Description:
The micro combustible gas sensor, resistance to Hydrogen Sulfide, strong resistance
to Silicon poison, ATEX, UL approval
Performance Characteristics:
Gases Detected: Combustible gases
Suitable for: methane, propane, butane, pentane, hexane, heptane, carbon monoxide and hydrogen
Unsuitable for: higher hydrocarbons, alcohols, ketones, esters, hydrogen sulphide and other sulphur
containing compounds
Range: 0-100% LEL
Operating Voltage: 3.30V d.c.
Detector Operating Current: 78±6mA
Poison Resistance: Resistant to H2S poisoning Superior Silicone resistance
H2S filter lifetime: typically 1000ppm hr
Output Sensitivity: 31±5 mV/%methane
T90 Response Time: <5 seconds (methane)
Operating Temperature Range *: -40°C to +55°C
Long Term Sensitivity Drift: <3% signal/month
Long Term Zero Drift: <5%LELmethane /month
Warranty Period: 12 months from date of dispatch